GOLD dach-podłoga (roof-floor)

GOLD dach-podłoga (roof-floor)

  • ground floors in residential, public and industrial buildings with normal loads
  • floors with underfloor heating systems
  • floors on all kinds of rigid ceiling structures
  • floors of public buildings
  • flat roofs
  • external ceilings
  • light structure roofs (trapezoid metal sheet roofs)
  • verandas, balconies
Termo Organika

Check, where you can buy our products

The product complies with the harmonized standard EN 13163:2012.

GOLD dach-podłoga EPS 100    EPS-EN 13163-T(2)-L(2)-W(2)-S(5)-P(5)-BS150-CS(10)100-DS(N)2-DS(70,-)2

Those are white or “spotted” boards produced by foaming polystyrene and intended for thermal insulation of floor, roofs and flat roofs. The boards may be produced with flat or milled edges enabling proper fitting. The boards are manufactured in standard dimensions: 1000 mm long, 500 mm wide, 10 mm thick, and then every 10 mm. A compressive creep deformation of 2% or less, when subjected to a permanent compressive stress of 30 kPa  (3000 kG/m2).

 

Polystyrene subjected to voluntary certification and recommendation procedure at Building Research Institute (Polish: ITB), not resulting from the system of assessment and verification of performance constancy.

Declared properties of GOLD dach-podłoga expanded polystyrene boards:

Dimension tolerance classes:  
  • thickness
  • T(2)± 2 mm
  • length
  • L(2)± 2 mm
  • width
  • W(2)± 2 mm
  • rectangularity
  • S(5)± 5 mm/m
  • flatness
  • P(5) 5 mm
    Bending strength levelBS150≥ 150 kPa
    Compressive stress at 10% relative deformationCS(10)100≥ 100 kPa
    Class of dimensional stability under constant normal laboratory conditionsDS(N)2± 0,2%
    Level of dimensional stability under specified temperature and humidity conditions (temp. 70°C, 48 h)DS(70,-)2 2%
    Declared thermal conductivity ratio λDat a temperature of 10°C0,036 W/(m*K)
    Fire reaction classE

    Declared value of thermal resistance RD depending on the thickness of GOLD dach-podłoga boards

    Thickness, mm102030405060708090100
    RD, m2K/W0,250,550,801,101,351,651,902,202,502,75
    Thickness, mm110120130140150160170180190200
    RD, m2K/W3,053,303,603,854,154,404,705,005,255,55

     Implementation

    The EPS boards should be applied in accordance with the manufacturer’s instructions, RTQ ITB 1261/2013 Technical and Quality Recommendations and  guidelines contained in a construction design. The basic guidelines for laying thermal insulation of floors and ceilings are as follows: make sure that the screed is flat and dry, otherwise level it out. The floors on the ground require a damp proofing barrier (in form of tar paper, PE film, bituminous and water-based sealants). Apply a separating layer of PE film in intermediate floors. Where the floor meets the wall, use an expansion jointing tape. Start laying the boards in the corner and place the first row of boards from the wall by pushing them against the expansion jointing tape. Subsequent rows should be laid with staggered  joints, avoiding crossing board joints. When all insulation is in place (can be in two or more layers), spread at least 0.2 mm thick PE film, to protect the boards against moisture and penetration of the screed in the spaces between the EPS boards. Where water-based underfloor heating is used, install the heating cables with suitable clips on the boards on which the PE film has already been spread. Please note that the thickness of the screed needs to be increased by the outer diameter of the underfloor heating cables.

     Caution

    Do not use the EPS boards in direct contact with the substances having destructive effect on polystyrene EPS, such as organic solvents (acetone, benzene, nitro), etc.

     Package, storage, transportation

    GOLD dach podłoga (roof-floor) boards are supplied only in the original manufacturer's packaging. The label on a package contains the following information: the name of a product, the manufacturer's name and a factory name, the date of production, EN 13163:2012 standard number, a code compatible with that standard, and declared technical features. GOLD dach-podłoga (roof-floor) boards should be protected against damaging and weather conditions.

    Certyficate of conformity ITB-851W(2.62MB).pdf  download
    Certification Mark(0.75MB).pdf  download
    Declaration of Preformance GOLD dach-podłoga 007-DoP-180306(1.61MB)pdf  download
    Certificate No 233/2021 of Type III Environmental Declaration(1.16MB)pdf  download

    MAYBE YOU WILL BE INTERESTED IN

    SUPERAKUSTIC floor
    Acrylic Paint EXTRA WHITE
    Back
    DE PRODUKTKATALOG | EN PRODUCT CATALOGUE | FR LISTE DES PRODUITS